Ethernet Powerlink
> Product Overview
> Powerlink Starter Kit
MN/CN Protocol Stack
> Safety Introduction
> Safety Software
> Powerlink Module
Powerlink IP Core
PL-IB 300/PCI
PL/CANopen Gateway
Config. Framework

ETHERNET Powerlink Safety Protocol Software

Software package for the development of
safety nodes (SN) and Safety Configuration Manager (SCM)


Product status Product announcement (this product is at the moment under development, dates on request)

Highlights

Overview

ETHERNET Powerlink Safety Protocol Software - Architecture of the EPLsafety software
Architecture of the EPLsafety software

SSC: Safety Stack Control: control of the EPLsafety software such as stack initialisation
SNMT: Safety Network Management: transmission, reception and processing of network management commands as well as distribution of the safety addresses
SCM: Safety Configuration Manager: configuration, verification and monitoring of safety nodes
SPDO: Safety Process Data Objects: cyclic exchange of process data and verification of time synchronization
SSDO: Safety Service Data Objects: server/client communication to access the object directory via the network
SOD: Safety Object Dictionary: access to the Safety Object Directory
SFS: Safety Frame Serialization: serialization and deserialization of the safety frames
SNS: Safety Node State: management of the operating states of the safety nodes
SERR: Safety Error Handling: logging of stack-internal errors
SCFM: Safety Control Flow Monitoring: monitoring of the correct program flow in accordance with SIL-3


Hardware concepts for EPLsafety
The Safety Integrity Level (SIL) that can be achieved with the EPLsafety software mainly depends on the hardware architecture used. The IXXAT EPLsafety software was created for use in SIL-3 devices. To meet the requirements of SIL-1, it is sufficient for example to use one single Safety Controller (SC) that carries out the safe application and the EPLsafety stack. To achieve SIL-3, the Safety Controller must also be designed as redundant.

ETHERNET Powerlink Safety Protocol Software - SIL-1/SIL-2 hardware architecture
SIL-1/SIL-2 hardware architecture

ETHERNET Powerlink Safety Protocol Software - SIL-3 hardware architecture
SIL-3 hardware architecture


Overview of functions
With its function modules, the IXXAT EPLsafety software enables the execution of all communication and back-up mechanisms necessary for EPLsafety. This includes the provision of a Safe Object Directory (SOD), Safe Process Data (SPDO) and Safe Service Data (SSDO) as well as time and CRC monitoring of the data packages. Zipping and unzipping of the EPLsafety frames in the transmission messages of the non-safe transmission protocol is carried out by the functions of the hardware-level firmware (SHNF) provided by the user. The inputs and outputs of the EPLsafety device must also be controlled by a special safety application. The SOD of the EPLsafety software is used as the data interface to the safety application.

ETHERNET Powerlink Safety Protocol Software - Integration of the EPLsafety software in the overall system
Integration of the EPLsafety software in the overall system

Scope of supply
- C-source code
- Pre-certified reference implementation
- Software license available for SN or SCM+SN
- Manual
- One-day code introduction
- Technical support

Supplementary services


Order number
On request ETHERNET Powerlink Safety Protocol Software