CANblue / Generic
CAN-Bluetooth-CAN Bridge and
CAN-Bluetooth Module with ASCII Protocol

The bridge mode allows the user to set-up a CAN-Bluetooth-CAN bridge by using two CANblue/Generic devices. Message exchange occurs on layer 2 and is transparent. The CANblue/Generic can also be used in systems that work with CANopen, DeviceNet or customer-specific protocols. Filters for CAN identifiers can be stored in the devices for data exchange via Bluetooth. By using more than two CANblue/Generic devices the coupling of the devices can be made dynamically. Depending upon the existing environmental conditions, the maximum distance between the CANblue/Generic devices is up to 100m.
ASCII Protocol Mode
In ASCII protocol mode, functions for transmitting and receiving CAN messages and for configuring the CANblue/Generic are available to the user based on simple ASCII commands. The CANblue/Generic is ideal for "non-Windows" systems or embedded platforms that will be connected wirelessly to CAN.
Technical Data
| Bluetooth interface | Bluetooth specification V2.0, Class 1 / +16,9 dBm (49 mW), 100m |
| Microcontroller | Infineon C161U, 36 MHz |
| Memory | 256 k Flash, 128 k RAM |
| CAN controller | 1 x SJA1000 |
| CAN bus interface | ISO/IS 11898-2 (High Speed) and ISO/IS11898-3 (Low-Speed), switchable, Sub D9 plug according to DS102, galvanic decoupled |
| Voltage supply | 9 - 30 V DC, 2.5 W |
| Temperature range | 0 ºC ... +55 ºC |
Certification |
CE, FCC |
| Housing | stable metal housing |
| Size | 85 x 72 x 35 mm |
Contents of delivery
- CANblue/Generic, manual
Order number
|